HVPSI ACN2192A100

Specifications

Specification Conditions Value
VI 120 V
Input Type AC
PI 25 W
VO -100000 V
PO 15 W
IOP 0.175 mA
Volt Reg. At Dynamic Load < 20 % VDC
Ripple At Full Load, Nominal Input < 1 % VPP
Line Reg. Output Change Over AC or DC Input Range At Nominal Load < 1 % VDC
Stability Over 8 hours, after 30 minute warm-up. At 25 °C ambient, fixed load, and fixed input. < 1 % VDC
Op. Temp. 0 to 60 °C
TCOEFF 0.06 % / °C
Store Temp. -40 to 85 °C
Humidity Non Condensing 0 to 95 %
Altitude 0 to 10000 Ft.

Notes

  • This power supply requires adequate ground connection for operation, failure to provide ground may result in failure of the power supply.