CKE 85HF-100
Specifications
Specification | Conditions | Value |
---|---|---|
VRRM | 1000 V | |
IFAVM | At TC (Case Temperature) | 85 A |
TC | 140 °C | |
VF | At Rated IF | 1.3 V |
TRR | – nS | |
Rø(JC) | 0.35 °C / W | |
Package Style | DO-5 | |
IFSM | At TJMAX | 1700 A |
I2T | At 60Hz | 14.5 kA2S |
rf1 | At TJMAX | – mΩ |
VF(TO) | At TJMAX | – V |
TJMAX | 150 °C | |
T | Non-lubricated Installation | 20 – 30 in-lb |
IRRM | At TJMAX | 4 mA |
Notes
- Current ratings require assembly on a suitably engineered heatsink, using a quality heat coupling compound.
- Data for all device parameters taken at 25˚C unless otherwise noted.
- Additional devices available on special request. Contact the factory.
- A «-» indicates a component that is a standard recovery device and no data was taken.
- For reverse polarity versions, replace the • with the letter «R» in the part number, e.g. 40HF•20 would become 40HFR20.