CK10W-24/68

Specifications

Specification Conditions Value
VRMS AC 20400 VAC
IMAX For 8 x 20 μs Pulse 10000 A
VR (L-N) 24 kV
VDC REF At 1 mA 34.4 kV
VRES At Steep of 1 x 10 µs Pulse 81.6 kV
VRES For Lightning Impulse 8 x 20 µs 70.4 kV
VRES For Switching Impulse 30 x 60 µs 60 kV
ISWC For Current Impulse 4 x 10 µs 100 kA
VBIL For Lighning Impulse 92 kV
VBIL At Power Frequency, Wet 1 Minute 64 kV
Str. Tor. 50 N m
Str. Can. 147 N m
Creepage 785 mm
A 1.18 in.
B 1.18 in.
C 11.26 in.
D 13.62 in.
E 2.32 in.
F 4.64 in.

Notes

  • Meets IEC600 99-4.